TEST
CONDITIONS
|
COMPRESSOR
HORSEPOWER %
|
EVAPORATOR
CAPACITY CHANGE % (BTU/HR)
|
COEFFICIENT
OF PERFORMANCE CHANGE %
|
COMPRESSOR
BODY TEMPERATURE CHANGE ° F
|
|
|
♦
1000 RPM, 350# HEAD PRESSURE
|
|
|
|
|
|
1
|
♦
130 ° F CONDENSER AIR FLOW
|
-1.51%
|
-0.92%
*
|
+
0.53%
|
+
1.5° F
|
|
|
♦
105° F EVAPORATOR INTAKE AIR
|
|
|
|
|
|
|
♦
2000 RPM, 270# HEAD PRESSURE
|
|
|
|
|
|
2
|
♦
130° F CONDENSER AIR FLOW
|
-3.90%
|
-0.38%
*
|
+
3.47%
|
-6.8°
F
|
|
|
♦
105° F EVAPORATOR INTAKE AIR
|
|
|
|
|
|
|
♦
3000 RPM, 250# HEAD PRESSURE
|
|
|
|
|
|
3
|
♦
130° F CONDENSER AIR FLOW
|
-2.90%
|
+
2.28%
|
+
5.22%
|
-10.2°
F
|
|
|
♦
105° F EVAPORATOR INTAKE AIR
|
|
|
|
|
|
|
♦
3000 RPM, 100# HEAD PRESSURE
|
|
|
|
|
|
4
|
♦
70° F CONDENSER AIR FLOW
|
-3.92%
|
-2.81%
*
|
+
0.42%
|
-1.6°
F
|
|
|
♦
70° F EVAPORATOR INTAKE AIR
|
|
|
|
|
|
|
♦
1000 RPM, 105# HEAD PRESSURE
|
|
|
|
|
|
5
|
♦
70° F CONDENSER AIR FLOW
|
-5.56%
|
-4.75%
*
|
+
1.24%
|
-0.9°
F
|
|
|
♦
70° F EVAPORATOR INTAKE AIR
|
|
|
|
|